Specifications and Characteristics

Electrical Specifications—Summary

24

Operating Manual for XDC Series Slave Power Supply

Electrical Specifications—Summary

Table A.1Specifications for 10V to 60V Models

Table A.2Drift Specifications for 10V to 60V Models

Models

10-600

20-300

30-200

40-150

60-100

Output Ratings:

Output Voltage

1

Output Current

2

Output Power

1. Minimum output voltage is <0.3% of rated voltage at zero output setting.
2. Minimum output current is <0.2% of rated current at zero output setting when measured with rated load resistance.

0–10 V
0–600 A
6000 W

0–20 V
0–300 A
6000 W

0–30 V
0–200 A
6000 W

0–40 V
0–150 A
6000 W

0–60 V
0–100 A
6000 W

Line Regulation:

3

Voltage

(0.01% of Vmax)

Current (0.05% of Imax)

3. For input voltage variation over the AC input voltage range, with constant rated load.

1 mV
300 mA

2 mV
150 mA

3 mV
100 mA

4 mV
75 mA

6 mV
50 mA

Load Regulation:

4

Voltage (0.05% of Vmax + 5 mV)
Current (0.1% of Imax + 20 mA)

4. For 0–100% load variation, with constant nominal line voltage.

10 mV
620 mA

15 mV
320 mA

20 mV
220 mA

25 mV
170 mA

35 mV
120 mA

Output Noise (0–20 MHz):

Voltage (p–p)

75 mV

75 mV

75 mV

75 mV

100 mV

Output Ripple (rms):

Voltage
Current

5

5. Current mode noise is measured from 10% to 100% of rated output voltage, full current, unit in CC mode.

10 mV
3100 mA

10 mV
1600 mA

12 mV
1000 mA

15 mV
750 mA

15 mV
450 mA

OVP Adjustment Range:

(0% to 103% of Vmax)

0–10.3 V

0–20.6 V

0–30.9 V

0–41.2 V

0–61.8 V

Efficiency:

6

6. Typical efficiency at nominal input voltage and full output power.

0.85

0.87

0.87

0.87

0.89

Models

10–600

20–300

30–200

40–150

60–100

Drift (30 minutes):

1

Voltage (0.04% of Vmax)
Current (0.6% of Imax)

1. Maximum drift over 30 minutes with constant line, load, and temperature, after power on.

4 mV
3600 mA

8 mV
1800 mA

12 mV
1200 mA

16 mV
900 mA

24 mV
600 mA

Drift (8 hours):

2

Voltage (0.02% of Vmax)
Current (0.04% of Imax)

2. Maximum drift over 8 hours with constant line, load, and temperature, after 30 minute warm-up.

2 mV
240 mA

4 mV
120 mA

6 mV
80 mA

8 mV
60 mA

12 mV
40 mA

Temperature Coefficient:

3

Voltage (0.04% of Vmax/°C)
Current (0.06% of Imax/°C)

3. Change in output per

°C change in ambient temperature, with constant line and load.

4 mV
360 mA

8 mV
180 mA

12 mV
120 mA

16 mV
90 mA

24 mV
60 mA