Specifications and Characteristics

Output Performance Specifications

30

Operating Manual for XDC Series Slave Power Supply

Time Delay From Output Enable Until Output Stable

2 s maximum
(Within regulation envelope)

Output Hold-Up Time – Power Off

Minimum 4 ms (at full load)

Output Hold-Up Time – Source Interruption

Minimum 4 ms with output deviation less than 5% of maximum output voltage after
source interruption.

Transient Response Time

1

Time to recover within 0.75% of rated output of previous level after step change in
load current between 50% and 100%.

Mode Crossover

Maximum deviation as a percentage of rated output voltage.

Peak–Peak and RMS Noise Bandwidth Limits

The frequency range for Peak to Peak measurements is 10 Hz–20 MHz.

The frequency range for RMS measurements is 10 Hz–100 kHz.

Maximum Remote Sense Line Drop Compensation

Minimum 3.8 V for each line, 5 V typical

Isolation

1. Time for the output voltage to recover within 0.75% of rated output of its previous level

after a step change in load current of up to 50% - 100% and 100% to 50% of rated
output

Mode

Time

Voltage Mode

3 ms stand alone unit

1

1. 96 ms typical in current sharing configuration

CV – CC Overshoot

1%

AC Input to Output

1350 V

ac

AC Input to Chassis

1350 V

ac

Output to Chassis

600 V

ac

TM-XDSL-01XN.book Page 30 Tuesday, November 5, 2002 3:22 PM