Specifications and Characteristics

AC Line Input Specifications

26

Operating Manual for XDC Series Slave Power Supply

AC Line Input Specifications

The input to the power supply requires the following specifications.

AC Line Input

Voltage

Operating

Ranges

Table A.5AC Line Input Specifications

Operating Range

nominal 208V

rms

(Standard)

nominal 400V

rms

(with HV-Input option)

190 to 242 V

ac

3

φ (3 wire + safety ground)

342 to 500 V

ac

3

φ (3 wire + safety ground)

Frequency Range

47 to 63 Hz

Maximum Peak In-rush Current at turn on 35 A

rms

Minimum Power Factor

1

nominal 208V

rms

(Standard)

nominal 400V

rms

(with HV-Input option)

0.95
0.9

Operating Current

nominal 208V

rms

(Standard)

Maximum

2

Typical

3

24 A
20 A

Operating Current

nominal 400V

rms

(with HV-Input option)

Maximum

4

Typical

5

13 A
11 A

1. At nominal input voltage and maximum power
2. At 190V

ac

input voltage, 55

°

C ambient temperature and maximum power

3. At 208V

ac

input voltage, 25

°

C ambient temperature and maximum power

4. At 342V

ac

input voltage, 50

°

C ambient temperature and maximum power

5. At 400V

ac

input voltage, 25

°

C ambient temperature and maximum power

TM-XDSL-01XN.book Page 26 Tuesday, November 5, 2002 3:22 PM

Advertising