Troubleshooting

5–4

No output voltage;

OVER

TEMP

indicator on; load is

more than 1000 W / 8 A
output current. The

AMPS

indicator is showing high
battery current.

Thermal shutdown.

Allow the unit to cool off.
Reduce the load if continuous
operation is required.

No output voltage; the

OVER

TEMP

indicator is on; the

load is less than 1000 W / 8 A
output current.

Thermal shutdown.

Improve ventilation; make sure the
inverter’s ventilation openings are not
obstructed; reduce the ambient
temperature.

No output voltage; the

OVER

LOAD

indicator is on.

Short circuit or wiring error.

Very high power load.

Check the AC wiring for a short circuit
or improper polarity (hot and neutral
reversed).
Remove the load.

Table 5-1 Troubleshooting Reference

Problem

Possible Cause

Solution