Zanussi ZTK123 User Manual

Page 14

Advertising
background image

14

Important:

Do not use the appliance without filters.

Cleaning the condenser unit

Clean the condenser when light

comes on.

The condenser is situated at the lower part of the

cabinet behind a small door. To open the door,

push the catch as per picture. During the drying

cycle or at the end, it is normal for water to be

present on the surface of the condenser insertion.

To pull out the condenser, first turn the two red

stops downwards and then remove the

condenser unit holding it at the handle.

Clean it with a brush and rinse it under the
shower if necessary.
Also clean the outside, removing all fluff.

Clean the rubber seal round the condenser cab-
inet and in the inner part of the small door with
a damp cloth.

Important:

Do not use pointed objects or utensils to clean

the spaces between the plates, as this could

damage the condenser and make it permeable.
Re-fit the condenser, turn the red stops upwards

and close the door.

Important:

Do not use this appliance if the condenser has

not been fitted.

Emptying the water reservoir

Water extracted from the laundry condenses

inside the machine and is collected in a reservoir.
The reservoir must be emptied after each drying

cycle to ensure efficient operation when the

machine is next used. The pilot light

reminds

you this operation.

Proceed as follows:

• Open the small door at the lower part of

the cabinet

• Turn the yellow stop upwards
• Pull out the reservoir
• Open the small cover and let water flow

down

• Close the small cover and re-insert cor-

rectly the reservoir

6

59

153