P

anel Operation and Displa

ys

Utility Displays

DME64N/DME24N Owner’s Manual

56

3 Mixer I/O
Displays whether the cascade signal is bus shared or not.

:

A DME64N connected directly to the mixer is

connected to a second DME64N on this unidirectional
channel.

Input on the same channel from other DME64N units
will be independent.

:

This channel is being used for bidirectional bus shared

connection between DME64N units. Input on the same

channel from other DME64N units will be summed.

Check Page

Even in an environment with no computer, you can check
the connections without using DME Designer by directly
connecting the DME64N/24N input/output.
The meter does not operate during a connection check.

MODE: OFF

Makes connections in the configuration used in the current
scene.
This is set to OFF when the unit is started.

MODE: Thru

Directly connects the Input and Output of each slot one-
to-one for each channel.
When input-only or output-only cards like AD or DA
cards are inserted in the slots, you cannot perform checks
in this mode.
In the DME24N, the internal AD and internal DA are
directly connected on each channel.

MODE: Summing

Sums all input signals coming from Inputs (-12dB),
without regard to device or card type, and outputs it
through all Outputs.

NOTE

Make sure that the Mixer I/O setting is the same for all cascaded
DME64N/24N units.

NOTE

This page will not appear on the ICP1 display.

Advertising