Yamaha DME24N User Manual

Page 60

Advertising
background image

Ref

erences

Error Messages

DME64N/DME24N Owner’s Manual

60

SLOT4 Sync Err

The DME64N clock is not synchronized with the clock of
the card installed in I/O slot 4.

Make sure that the DME64N and the card or external
source supplying the word clock are set to use the same
word clock.

Synchronizing
Do not turn off

Data is being received from the computer. Do NOT turn
power off while the unit displays this message.

Updating
Do not turn off

Data is being received from the computer. Do NOT turn
power off while the unit displays this message.

WCLK Unlocked

A usable word clock signal is not being received or
cannot be detected.

Recheck all word clock connections and internal
parameters.

WCLK In Sync Err

The DME64N/24N clock is not in sync with the clock
signal being received at the WORD CLOCK IN]
connector.

Make sure that the DME64N/24N and the card or
external source supplying the word clock are set to use
the same word clock.

Message

Meaning

Action

Advertising