Operating AC Appliances

Low-Battery Alarm

While in use, when the battery reaches 11 Vdc, the
Low-Battery Alarm will sound and display an error code
indicating that battery is low and the unit is about to be
shutdown to prevent battery damage.

When the battery reaches 10.5 Vdc, the unit will
automatically disconnect power to the AC sockets.

If the alarm sounds, disconnect any loads that may be in
use and recharge the unit as soon as possible.

Figure 3-6 Operating AC Appliances

1. Press and hold the AC button for one

second to activate the AC sockets.

2. Check the state-of-charge to ensure

the battery is fully charged.

3. Open the AC socket cover.

4. Plug the appliance into one of the AC

sockets and turn the appliance on.

5. Unplug or turn off the appliance when

not in use to conserve energy.

6. Press and hold the AC button again

to deactivate the AC sockets.

1.

Note

: Recharge the Powerpack

as soon as battery level dips below
normal.