Leveling the appliance, Connecting to gas supply, Fitting the stability bracket – Zanussi ZKG5030 User Manual

Page 31: Important

Advertising
background image

31

Curtains must not be fitted immediately
behind the appliance or within 150mm of the
sides of the hotplate. If fitted next to or
between two base units a minimum space of
1mm must be left between each unit and the
sides of the appliance. The hotplate must be
set to a minimum of 7mm above the adjacent
units. (Note: The leveling feet fitted to the
appliance will achieve a nominal height of
907mm -5+ 13mm. Base units not meeting
the above conditions must be a minimum of
100mm away from the hotplate.

Leveling the appliance

Adjustment to suit floor conditions or height
is obtained by rotating clockwise or anti
clockwise the feet at the front and rear of the
appliance. A spirit level should be placed on
one of the shelves to confirm the appliance
is correctly leveled.

Connecting to gas supply

This appliance is designed to be installed
with an appliance flexible connection only.

Supply piping should not be less than R

3

/8.

Connection is made to the Rc ½ (½” B.S.P.)
female threaded entry pipe located just
below the hob level on the rear left hand side
of the appliance.

IMPORTANT!

ONLY LIQUID SEALANTS TO BE USED
WHEN INLET GAS PIPE IS FITTED I.E.: DO
NOT USE P.T.F.E. SEALANT TAPE.

Carry out a gas tightness test after
connecting to the gas supply.

The gas bayonet connector must be fitted in
the shaded area indicated.

250mm

200mm

650mm

400mm


Take into account that it must be possible to
pull the appliance forward sufficiently.
Ensure the hose does not become trapped
when pushing the appliance into position.

IMPORTANT!

FLEXIBLE TUBING USED MUST COMPLY
WITH BS.669 CURRENT EDITION.

Fitting the stability bracket

It is recommended that if the appliance is to
be installed with a flexible supply pipe, a
stability bracket be fitted and is available
from your supplier (see Important Safety
Requirements). These instructions should be
read in conjunction with any leaflet packed
with the stability bracket.


1.

Place the appliance in its intended position
and level appliance.

2.

Mark off 250mm from the left hand side of
the appliance as shown in dimension 'A'.
This is the centre line of the fixing bracket.

Advertising