Zenith controls, Example, Switch types – GE Zenith ZTS Series User Manual

Page 10: Zts series ordering information

Advertising
background image

A Product of GE Industrial Systems

General Electric Company

830

West

40

th

Street, Chicago,

IL 60609 USA

773 299-6600

, Fax:

630 850-6899

www.geindustrial.com

g

GE

Zenith Controls

ZTS Series

Ordering Information

Model/Type

Ampere

Size

Switched

Poles

Enclosure

Type

Operational

Voltage

Accessories

A B

Consult Table Below

0

4

40 amps

N

Type 1 Enclosed

Open Style Unit

B

2 Poles

F

4 Poles

E

3 Poles

B 0

Entelli-Switch 250

Microprocessor

Control Unit

Standard (Open Transition)

Z

Example

ZTSCT0B0040F-N0140STD

This number string shows the correct format for a

ZT

S Model Automatic Transfer Switch with closed transition,

an Entelli-Switch 250 microprocessor control unit, Utility - Generator, 400 amps, 4 pole,

NEMA

Type 1 enclosure,

120/208V 3Ø, 4 wire, 60 Hz system with the standard group of accessories.

T D

S

M

X E

E

B 0

Control

Panel

Switch Types

Standard: Unless otherwise noted, the standard
switch with quick transfer will be supplied.

Delayed Transition: When ordered as the ZTSD,
the delayed transition switch offers time delay during
transfer from one position to the other. This is primarily
for transfer of large motor or inductive loads.

Closed Transition: When ordered as the ZTSCT,
the closed transition switch offers two basic modes
of operation. During a failure of one source or an out
of specification condition, the

ZTSCT

Model operates

as a standard delayed transition switch (

ZTSD

Model).

This sequence allows clear separation of an unreliable
source from an available one.

Bypass: When ordered as the ZBTS, the bypass
transition switch offers a draw-out mechanism, with
electrical and mechanical interlocks for secure removal
after load bypass. In this way the transfer switch
and/or the control panel may be tested, isolated and
removed for maintenance without load interruption.

Then choose

additional

accessories

0

0

8

80 amps

0

1 0

100 amps

0

1 5

150 amps

0

2 0

200 amps

0

2 2

225 amps

0

260 amps

4 0

400 amps

0

6 0

600 amps

0

8 0

800 amps

0

0 0

1000 amps

1

2 0

1200 amps

1

6 0

1600 amps

1

0 0

2000 amps

2

6 0

2600 amps

2

0 0

3000 amps

3

Config.

0

Utility - Generator

M

Manual

U

Utility - Utility

0 0

0

2 6

0

Type 4 Enclosure

Type 12 Enclosure

Type 4X Enclosure

Type 3R Enclosure

0 1

N 1 2

N 3 R

N 0 4

N 4 X

X 0 0

T S

Z

Delayed Transition

0 0

D

T S

Z

Closed Transition

T 0

C

T S

Z

Standard (Open Transition) w/ Bypass

0 0

S

B T

Z

Delayed Transition w/ Bypass

D 0

S

B T

Z

Closed Transition w/ Bypass

C T

S

B T

Z

3 0

300 amps

0

0 0

4000 amps

4

O N

C

E N

S

P E

S

S G

P

A

B

Voltage

Phase

Config.

Hz

1

0

120

1

2 wire

60

2

0

120/240

1

3 wire

60

2

1

120/208

3

3 wire

60

3

0

240

3

3 wire

60

3

1

208

3

3 wire

60

3

2

220

3

3 wire

50

3

3

120/240

3

4 wire

50

3

4

110/220

3

4 wire

60

3

5

139/240

3

4 wire

60

3

8

120/240

3

4 wire

60

4

0

120/208

3

4 wire

60

4

1

127/220

3

4 wire

60

4

2

127/220

3

4 wire

50

5

0

480

3

3 wire

60

5

1

440

3

3 wire

60

5

2

440

3

3 wire

50

5

5

460

1

3 wire

50

5

7

480

1

2 wire

60

5

8

254/440

3

4 wire

60

6

0

575

3

3 wire

60

6

1

347/600

3

4 wire

60

7

0

277/480

3

4 wire

60

7

1

277

1

2 wire

60

7

4

266/460

3

4 wire

60

7

5

460

3

3 wire

60

8

0

120/240

2

4/5 wire

60

8

2

380

1

2 wire

50

9

0

240/416

3

4 wire

60

9

1

220/380

3

4 wire

60

9

2

220/380

3

4 wire

50

9

3

240/416

3

4 wire

50

9

7

380

3

3 wire

60

Note: Operating voltage must be specified at time of order.

Only the most common voltages are shown above.

S

M

S

M

S

M

S

M

S

M

S

Contents contained in this document are subject to

change without notice. Contact GE to verify details.