ZTS Series

Accessory Definitions

PB-5066

P

age 6

M85
Digital Meter Includes M84 functions plus

unbalance 256 samples/cycle data logging,

waveform capture and sag/swell capture.

M86
Digital Meter Includes M85 functions plus

large graphical screen display with Ethernet

communications port.

N1
Running Time Indicator - Door mounted

N2
Operation Counter - Door Mounted

P1
Engine Start Timer (adjustable to 6 sec.)

P2
Engine Start Timer (adjustable to 300 sec.)

Q2
Peak shave/remote load test/area protection -

Relay (S.P.D.T.) (Need to specify voltage - 120 VAC,

24 VAC, 24 VDC - 120V default standard)

Q3
Inhibit transfer to emergency (Source 2) (load add

relay) - Relay (S.P.D.T.) (Need to specify voltage -

120 VAC, 24 VAC, 24 VDC - 120V default standard)

Q7
Inhibit transfer to normal (Source 1) - Relay

(S.P.D.T.) (Need to specify voltage - 120 VAC, 24

VAC, 24 VDC - 120V default standard)

R1-1/R1-3
Over Voltage sensing for normal (Source 1)

single (R1-1) or three (R1-3) phase

R15/R15D
Load Shed. Should Source 2 become overloaded,

a signal can be given to switch to the dead

or Mid position.

R16
Phase rotation sensing of Normal (Source 1) and

Emergency (Source 2)

R26/R26D
Interruptable Power Rate Provisions.

Allow transfer out of Source 1 position to Mid

position or dead Source 2. Alarm and Pre-Signal

circuit included. (Need to specify voltage - 120 VAC,

24 VAC, 24 VDC - 120V default standard)

R50
In Phase monitor between Normal (Source 1) and

Emergency (Source 2) to allow transfer

S5P
Microprocessor activated auto/manual retransfer

selector switch for trnsferring to Normal (Source 1)

(includes microprocessor activated YN accessory)

S12P
Microprocessor activated auto/manual retransfer

selector switch for trnsferring to Normal

(Source 1) (includes microprocessor activated

YN & YE accessory)

S13P
Microprocessor activated commit/no commit

on transferring to Emergency (Source 2)

(with enable/disable)

S14
Keyed selector switch for

(retransfer to normal-test-auto)

SW1
Auto/Off/Start Engine control selector -

Door mounted (keyed or non-keyed

operation available)

SW2
Auto/Off Engine control selector - Door mounted

(keyed or non-keyed operation available)

SW3
Source Priority Selector Switch - Door mounted

Allows selection of Source 1 or Source 2 to be

the Prime Source. Transfer Switch will transfer to

selected Prime Source if that Source is available.

(keyed or non-keyed operation available)

T
Retransfer to normal adjustable time delay

T3/W3
Pre-signal contact on transfer to Normal (Source 1)

or Emergency (Source 2) during test.

U
Engine stop /cool adjustable cool down timer

UMD
Pre and ppost transfer output adjustable time range.

Functions in both directions. Includes 2 circuits.

Additional circuits available.

VI
Voltage imbalance between phases (3 Phase only)

W
Adjustabvle time delay on transfer to Emergency

(Source 2)

YEN
Bypass transfer timers function (soft switch in control)

ZNET
Microprocessor Communication Module