40, 80

100, 150

225

260, 400

600

1600
2000

3000

4000

800, 1000, 1200

2, 3

4

2, 3

4

2, 3

4

3
4
3
4
3
4

2, 3

4

24 (61)
24 (61)

46 (117)
46 (117)
66 (168)
74 (188)

90 (229)
90 (229)
90 (229)
90 (229)
90 (229)
90 (229)

74 (188)
74 (188)

18 (46)
18 (46)
24 (61)
24 (61)
24 (61)
30 (76)

30 (76)
36 (91)
30 (76)
36 (91)

40 (102)

46.5 (118)

30 (76)

40 (102)

11.13 (28)
11.13 (28)
14.13 (36)
14.13 (36)
19.75 (50)
19.75 (50)

48 (122)
48 (122)
48 (122)
48 (122)
60 (152)
60 (152)

19.75 (50)
19.75 (50)

A
A
A
A
B
B

C
C
C
C
C
C

B
B

21 (10)
24 (11)
70 (32)
75 (34)

165 (75)
185 (84)

345 (156)
450 (204)
465 (211)
670 (304)
770 (349)

1025 (465)

190 (86)
210 (95)

57 (26)
60 (27)

165 (75)
170 (68)

380 (172)
430 (195)

1010 (458)
1160 (526)
1130 (513)
1395 (633)
1595 (723)
1850 (839)

455 (206)
540 (245)

1 – 7

1 – 7

1 – 8

1 – 8

1 – 10

1 – 10

1 – 8

Ampere

Rating

Poles

Height

(A)

Width

(B)

Depth

(C)

Reference

Figure

Open

Type

NEMA 1

Application Notes

NEMA 1 Enclosed

Weight

ZTS

Model Transfer Switches

1. Metric dimensions (cm) and weights (Kg) shown in parenthesis adjacent

to English measurements in inches and pounds.

2. Includes 1.25" door projection beyond base depth. Allow a minimum of 3"

additional depth for projection of handle, light, switches, pushbuttons, etc.

3. All dimensions and weights are approximate and subject to change

without notice.

4. Special enclosures (NEMA 3R, 4, 12, etc.) dimensions and layout may differ.

Consult the GE Zenith factory for details.

5. Normal and emergency may be ordered inverted on any switch.

The load may be inverted 600-1200 amps. Consult the factory for details.

6. Special lug arrangements may require different enclosure dimensions.

For certified drawings, contact the GE Zenith factory.

7. Packing materials must be added to weights shown. Allow 15% additional

weight for cartons, skids, crates, etc.

8. Add 4" in height for removable lifting lugs.
9. Lug adapters for 3000-4000 amp limits may be staggered length for ease

of entrance. Consult the GE Zenith factory for details.

10. Ventilation louvers on both sides of enclosure at 3000 and 4000 amps.

One must be clear for airflow with standard cable connections.

Application Notes:

Notes:

*

Line and load terminals are located in rear and arranged for bus bar connection.
Terminal lugs are available at additional cost. Contact factory for more details.

1. Special terminal lugs and neutral bars are available at additional cost. Contact factory and advise cable sizes

and number of conductors per pole.

2. Fully rated neutral provided on 3 phase, 4 wire system.
3. Normal and emergency may be ordered inverted on any switch. Load may be inverted 600-1200 amps. Consult the factory for details.

es:

4. Lug adapters for 3000-4000 amp units may be staggered length for ease of entrance. Consult the factory for details.

5. Special lug arrangements may require different enclosure dimensions. For certified drawings, contact the GE Zenith factory.

AL-CU UL Listed Solderless

Screw-Type Terminals for

External Power Connections

Switch

Normal,

Switch

Normal

Size

Emergency,

Size

Emergency,

Amps

& Load Terminals

Amps

& Load Terminals

Cables/

Wire

Cables/

Wire

Pole

Ranges

Pole

Ranges

40-150

1

#8 to 3/0

800/1000

4

#2 AWG to

AWG

/1200

600 MCM

225

1

#4 AWG to

1600

600 MCM

260

1

#4 AWG to

2000

600 MCM

400

1

#4 AWG to

3000

600 MCM

600

2

#2 AWG to

4000

600MCM

*

P

age 9

PB-5066

ZTS Series

Dimensional Specifications / Power Connection Terminals

A

C

B

Figure A

A

C

B

Figure B

Figure C