8e6 Technologies ProxyBlocker MSA-004-005 User Manual

Page 13

Advertising
background image

8

e

6 P

roxy

B

locker

Q

uick

S

tart

G

uide



Optional: Install the Traditional UP Racks

After you have installed the inner rails on the chassis, you are ready to install the outer

rails of rail assemblies to the rack.

NOTE: The rails are designed to fit in the racks with the depth of 28” to 33”.

Determine the placement of each component in the rack before you install the

rails.

• Install the heaviest server components on the bottom of the rack first, and

then work up.

1. In the package, locate a pair of front (short) and rear (long) brackets. Please note

that the brackets are marked with Up/Front Arrows (front) and Up/Rear arrows (rear).

2. Secure the front (short) bracket (marked with the Up/Front arrows) to the outer rail

with two Type G screws. (See the previous page for a description of the Type G

screw.)

3. Attach the rear (long) bracket to the other end of the outer rail and secure the rear

(long) bracket to the outer rail with a Type G screw as shown below.

4. Measure the depth of your rack and adjust the length of the rails accordingly.

5. Repeat the same steps to install the other outer rail on the chassis.

6. Secure both outer rail assemblies to the rack with Type H screws and Type I wash-

ers. (See the previous page for descriptions of Type H and Type I hardware compo-

nents.)

Advertising