Choosing a suitable site, Rack-mounting – 3Com 3C16951 User Manual

Page 24

Advertising
background image

24

C

HAPTER

2: I

NSTALLING

THE

S

WITCH

Choosing a Suitable
Site

The Switch is suited for use in an office environment where it can be
mounted in a standard 19-inch equipment rack, or free standing.
Alternatively, the Switch can be rack-mounted in a wiring closet or
equipment room. A rack-mounting kit, containing two mounting
brackets and six screws, is supplied with the Switch.

When deciding where to position the Switch, ensure that:

You are able to meet the configuration rules detailed in

“Configuration Rules for Fast Ethernet”

on

page 20

.

The Switch is accessible and cables can be connected easily.

Cabling is away from:

Sources of electrical noise such as radios, transmitters and
broadband amplifiers

Power lines and fluorescent lighting fixtures

Water or moisture cannot enter the case of the Switch.

Air-flow is not restricted around the Switch or through the vents in the
side of the Switch. We recommend that you provide a minimum of
25mm (1in.) clearance.

No more than four Switch units are placed on top of one another, if
the units are free standing.

Rack-mounting

The Switch is 1.5U high and fits in most standard 19-inch racks.

CAUTION: Disconnect all cables from the Switch before continuing.
Remove all self adhesive pads from the underside of the Switch if they
have been fitted.

1 Place the Switch the right way up on a hard flat surface, with the front

facing towards you.

2 Locate a mounting bracket over the mounting holes on one side of the

Switch, as shown in

Figure 7

.

16950ua.bk Page 24 Thursday, April 29, 1999 1:28 PM