Cleaning the air filters and vents, Replacing the lamp and air filters – Epson 7900p User Manual

Page 21

Advertising
background image

Epson PowerLite 7900p Projector

9/04

Epson PowerLite 7900p Projector

-

21

Cleaning the Air Filters and Vents

Clean the air filters and air intake vents after every 100 hours
of use. If they are not cleaned periodically, they can become
clogged with dust, preventing proper ventilation. This can
cause overheating and damage the projector.

Follow these steps:

1. Turn off the projector and unplug the power cord.

2. To clean the intake vents, Epson recommends using a small

vacuum cleaner designed for computers and other office
equipment. If you don’t have one, gently clean the vents
with a soft brush (such as an artist’s paintbrush).

3. Gently turn the projector over and remove the filters from

the side and bottom of the projector. Then use a small
vacuum cleaner or soft brush to clean the two filters. Slide
the filters back into place when you’re done.

4. If the dirt is difficult to remove or a filter is broken, replace

the filters as described below. Contact your dealer or call
Epson at (800) 873-7766 in the United States to obtain
new ones. In Canada, please call (800) 463-7766 for dealer
referral.

Replacing the Lamp and Air Filters

The life span of the projection lamp is about 2000 hours. It is
time to replace the lamp when:

❏ The projected image gets darker or starts to deteriorate.
❏ The message

LAMP REPLACE

appears on the screen when

the lamp comes on (after about 1900 hours) and the

lamp warning light is flashing orange. To maintain

projector brightness and image quality, replace the lamp as
soon as possible.

❏ The

lamp warning light is flashing red (the lamp is

burnt out).

Contact your dealer or call Epson at (800) 873-7766 in the
United States for a replacement lamp. Request part number
V13H010L22. In Canada, please call (800) 463-7766 for
dealer referral.

Note: When you get a replacement lamp for your projector, new
air filters are included. You should replace the filters when you
replace the lamp. You can check how long the lamp has been in
use (see page 22).

Warning: Let the lamp cool fully before replacing it. In the
unlikely event that the lamp has broken, small glass fragments
may be present and should be removed carefully to avoid injury.

Follow these steps to replace the lamp and air filters:

1. Turn off the projector.

2. When the P power light stops flashing, unplug the power

cord.

3. Let the projector cool for at least half an hour (if it has been

on). The lamp is extremely hot immediately after use.

4. Turn the projector upside-down and remove the air filters

at the side and bottom of the projector.

5. Insert the two new air filters. They should click into place.

Slide the filter
up here . . .

. . . and here

Lower the handle

Slide the filter
up here . . .

. . . and here

Lower the
handle

Advertising