Festool CTM 55 E User Manual

Page 13

Advertising
background image

13

nesium, aluminium etc. - Risk of explosion!

- Do not use to extract fl ammable or explosive

liquids (e.g. petrol, thinners) - Risk of explo-
sion
!

- Do not use to extract aggressive liquids/dry

materials (e.g. acids, alkalis, solvents).

- This mobile dust extractor is suitable for extrac-

ting paint dust.

- Remove plug from mains socket when not in use

and before maintenance work.

- Do not pull plug out of mains socket by its ca-

ble.

- Protect the cable against heat, oil and sharp

edges.

- Check the plugs and cables regularly and have

them replaced by an expert if damaged.

- Do not leave devices out in the rain.
- Do not lift or carry the devices by their handles

using a crane hook or lifting gear.

- The device may only be used by persons who

have been trained in its use and who are au-
thorised to do so.

- If noxious dusts have been extracted, the vacuum

cleaner and all accessories must be completely
cleaned (inside and outside) by suction and
wiping, before removal from the contaminated
area. Parts that cannot be completely cleaned
are to be packed for transport in a plastic bag
with an airtight seal. The suction opening (1.14)
must be sealed with the blanking plug (1.13) for
transport purposes.

- For safety reasons, only operate the machine

using a totally earthed socket.

3

Appliance preparation and initial opera-
tion

The accessories are delivered horizontal in the
container (2.10), and must be removed prior to
initial operation.

3.1 Power

supply

The line voltage and frequency must
correspond with the data on the ratings
plate!

Make sure that the vacuum cleaner is switched off
when you plug the power cable in.
The antistatic system (AS)
Friction in the suction hose causes electrostatic
charges which can result in unpleasant electric
shocks for the operator. In order to conduct these
static charges to earth, the extraction units are
provided with an antistatic system as a standard

feature. However, antistatic hoses and accessories
have to be used in this case. The antistatic function
will only work if the plug is plugged into a totally
earthed socket.

3.2

On/off switch (1.3)

In position 0 the vacuum cleaner is switched off
and the appliance plug socket (1.7) is dead. Be-
fore switching on, the rotary knob (1.2) must be
adjusted to the diameter of the connected suction
hose.

Two modes of operation are possible:
a)

Switch position „MAN“

The appliance plug socket is dead.
The cleaner motor starts immediately.

b)

Switch position „Auto“

The appliance plug socket is live.

Before turning the switch to the „Auto“
position, ensure that the tool connected
to the appliance plug socket is switched
off.

The cleaner motor starts only when the tool con-
nected to the appliance plug socket is switched
on.

3.3

Suction force regulator (1.4)

The suction force regulator can be used to vary the
suction capacity. This permits a precise adaptation
to different substances to be picked up.

3.4 Temperature

control

A temperature fuse switches the dust extractor off
before this reaches a critical temperature to pro-
tect against overheating - switch dust extractor off
and leave for around 5 minutes to cool down.
If the dust extractor still cannot be switched back
on, please consult a Festool-service centre.

3.5

Connecting an electric tool

Observe the maximum connected load on
the appliance plug socket (see “Technical
Data“)!

Make sure that the electric tool is switched
off when plugging it in and unplugging
it.

Connect the electric tool to the appliance plug
socket (1.7).

Advertising