Festool CTH 48 E-LE-AC CLEANTEX User Manual

Page 17

Advertising
background image

CTM 48 E LE EC, CTL 48 E LE EC

17

GB

Observe the following when extracting

dust generated by operating electric power

tools:
If the exhaust air is discharged back into the

room, the air renewal rate L within the

room must be sufficient. The volume of air

discharged back into the room must not ex-

ceed 50% of the fresh air volume flow (room

volume V

R

x air renewal rate L

W

). Observe all

the relevant regional regulations.

Remember: A moist main filter clogs more

quickly when extracting dry materials.

Therefore, dry the main filter before extract-

ing dust or replace the damp filter with a dry

one.
8.3

Extracting fluids

Before extracting fluids, remove the filter

bag (see Chapter 7.8). We recommend using

a special wet filter.
The dust extractor stops automatically when

the maximum level is reached.

8.4

After finishing work

X

Switch off the mobile dust extractor and

disconnect the plug.

X

Wind up the mains power cable.

X

Empty the dust container.

X

Only CTM 48 E LE EC: Close off the ex-

tractor opening

[1-2]

using the sealing

plug

[1-1]

.

The machine shall be stored indoors

only.

X

Place the mobile dust extractor in a dry

room inaccessible to unauthorised users.

9

Service and maintenance

Damaged safety devices and components

must be repaired or replaced in a recognised

specialist workshop, unless otherwise indi-

cated in the operating manual.
Observe the following instructions:
– A dust test must be performed at least

once a year by the manufacturer or an in-

structed person. This test may include

checks to determine whether the filter is

damaged, the machine is sealed properly

and the monitoring features are function-

ing correctly.

– During maintenance and repair work, all

components that cannot be cleaned satis-

factorily must be replaced. The old compo-

nents must be sealed in impermeable

plastic bags prior to disposal in compliance

with applicable regulations for this type of

waste.

– Provided maintenance personnel or other

persons in the vicinity are not endangered,

the user must dismantle and clean the ma-

chine prior to performing maintenance

work. Appropriate precautionary measures

include decontaminating the machine prior

to disassembly, making provisions for lo-

cally filtered forced ventilation at the loca-

tion of machine disassembly, cleaning the

maintenance area and appropriate person-

al protective equipment.

CAUTION

Escaping foam and fluids

X

Switch off the machine immediately and

empty the dirt trap.

WARNING

Hazardous dust
Damage to the respiratory passage

X

Wipe down the mobile dust extractor and

clean all accessories thoroughly using the

extractor (inside and out) before removing

from the working area.

X

Parts that you were not able to clean thor-

oughly must be sealed in an airtight plastic

bag prior to transportation.

X

Wear a dust mask!

WARNING

Risk of injury, electric shock

X

Always disconnect the mains plug from the

socket before performing maintenance

work on the machine!

X

All maintenance and repair work which re-

quires the motor housing to be opened

must only be carried out by an authorised

service workshop.

Advertising