Here are the descriptions of every setup item:

Item

Description

Enable RS-485 Check this box to enable RS-485 functionality.
Use Pelco-D

Select this option and RS-485 interface will output pan-tile control signal
in Pelco-D format. This format is widely accepted by most of pan-tilt
camera cradles.

You have also input pan-tilt camera cradle’s address code in ‘Address’
field (number must be between 0~255). This code must be identical to
pan-tilt camera cradle’s address code.

Use Custom
Protocol

When the pan-tilt camera cradle does not support Pelco-D protocol, you
can define a protocol’s detail by this function.
Please refer to pan-tilt camera cradle’s user manual to define the
protocol.

- Baud Rate: Select data baud rate of RS-485 interface that pan-tilt

camera cradle will accept. When the length of RS-485 connection is
very long (longer than 200M), it’s not recommended to use high
speed connection (greater than 2400bps).

- Data Bits: Select data bits of RS-485 connection.
- Parity: Select parity bit: odd, even, or space.