Wan link health detection – Edimax Technology BR-6641 User Manual

Page 30

Advertising
background image

BR-6641 User Manual

29

Basic Setting:

Field Value

Description

Down Stream

The down stream (inbound) bandwidth of the
WAN link, for example 25600 (Kbps).

Up Stream

The up stream (outbound) bandwidth of the
WAN link, for example 25600 (Kbps).

Port Speed

Auto
10Mbps/Half duplex
10Mbps/Full duplex
100Mbps/Half
duplex
100Mbps/Full duplex

The speed and duplex of WAN Port. You can
set it manually or system can got it
automatically.

Health
Detection

Never
Always
Only when no
packet is received

This function is used to configure the WAN
link health detection mechanism for the
specific WAN link.

Address IP

Address

IP Range

Input the IP Address of BR-6641 in WAN. It
can be:
IP Address
IP Range

Gateway

Input the predefined Gateway, e.g.:
211.21.40.254.

Subnet Mask

Input the Subnet Mask.

IP(s) in DMZ

IP Address
IP Range

Input the IP Address of BR-6641 in DMZ. It
can be:
IP Address
IP Range

Table 3.1 Standard Mode / Basic Setting

WAN Link Health Detection:

This function allows MIS to configure how WAN link health detection is performed.

By fine-tuning certain parameters, an MIS can adjust BR-6641 to match a

particular network structure and/or a particular ISP.

For WAN link health detection, BR-6641 sends out ICMP or TCP packets and

monitors responses to determine the statuses of those links. In the WAN Link

Advertising