3. Fault Repair

for the user and engineer

Fault

Cause

Rectification

No hot water despite hot water
fitting being fully open.

No power.

User / Engineer:

Check fuses on domestic system.

Limescale on jet regulator.

User / Engineer:

Clean or replace jet regulator on fitting.

Filter dirty.

Engineer:

Clean or replace filter H (3a) in the cold water con-
nection.

Protective temperature restrictor
(STB) has tripped.

Engineer:

Eliminate cause of fault (replace thermostat). Note:
STB resets automatically when the unit power supply
is switched off.

Boiling sound in heater.

Limescale in heater.

Engineer:

Descale unit.

Fitting still drips after turning off.

Residual water is not retained in
the fitting outlet.

Engineer: Replace

jet

regulator on fitting outlet. Change outlet

or fitting.

Fitting drips on heating.

Frequent small draw-off quantities
(< 0,4 l/min).

User: Change

draw-off behaviour (> 0,4 l/min).

Unsuitable fitting
e.g. Antitropf fitting WAT.

Engineer:

Replace fitting (see 1.7 “Special Accessories”).

Antitropf-function faulty.

Engineer:

Replace unit.

Table 2