Acclaim Lighting ART IO User Manual

Page 37

Advertising
background image

GPI
The GPI section signals measured by the input ports. It allows you to switch a port between Digital and
Analog. When set to Analog you need to calibrate the input range so the Art IO knows the minimal and
maximum voltage it can receive on that port. The Art IO supports any voltage inside the range of 0V and
10V.

Follow these steps to calibrate a port:

1.

enable the 'Calibrate' button

2. apply the minimal voltage

3. apply the maximum voltage

4. disable the 'Calibrate' button

Caution: Applying a voltage >10V could damage the Art IO.

GPO
This section shows you the status of each relay and allows you to manually change it.

RS-232
This section gives you control of the RS-232 properties. Make sure these settings match the device you
are communicating with.

UDP
In this section you can set the port number on which the Art SSC will listen out for UDP messages. The
IP addresses and port numbers for outgoing UDP messages are set in the tasks at the Show Control
page.

OSC
Set the port number on which the Art SSC will listen for OSC messages in this section.

Also you need to fill in the addresses of the devices you would like to be receiving the OSC messages
being sent out by the Art SSC. In these IP Out fields you enter both IP address and port number; in the
following syntax: “ipaddress:port”. E.g. to send OSC messages to your device at 192.168.1.99 and port
number 7070, you would fill in: “192.168.1.99:7070”.

You can specify up to 4 addresses. Fill in “0.0.0.0:0” in each field you do not need to use.

IP
For setting up the IP address and sub-net mask of the Art SSC. The 'Router' field is only required when
doing Port Forwarding.

36

Advertising