9.0. Commands

9.1. Control Commands

The Control Commands are in charge of the internal operation of the ACR38x. They do not directly

affect the card inserted in the ACR38x and are therefore independent of the selected card type.

9.1.1.

GET_ATR_STAT

This command returns relevant information about the particular ACR38x model and the current

operating status such as the firmware revision number, the maximum data length of a command and

response, the supported card types, and whether a card is inserted and powered up or not.
Command Format

Header Instruction

Data length

01h

01h

00h

00h


Response Data Format

Header Status

Data length

INTERNAL

MAX_C MAX_R C_TYPE C_SEL C_STAT

LEN

01h

Where:
INTERNAL

10 bytes data for internal use only.

MAX_C

The maximum number of command data bytes.

MAX_R

The maximum number of data bytes that can be requested to be transmitted in a

response.

C_TYPE

The card types supported by the ACR38x. This data field is a bitmap with each bit

representing a particular card type. A bit set to '1' means the corresponding card type

is supported by the reader and can be selected with the SELECT_CARD_TYPE

command. The bit assignment is as follows:

Byte

1

2

card type 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0


See

Appendix A for the correspondence between these bits and the respective card

types.

C_SEL

The currently selected card type as specified in a previous SELECT_CARD_TYPE

command. A value of 00h means that no card type has been selected.

C_STAT

Indicates whether a card is physically inserted in the reader and whether the card is

powered up:

00h: No card inserted
01h: Card inserted, not powered up
03h: Card powered up