Usb interface, Communication parameters, Endpoints – ACS ACR38 SAM Smart Card Reader User Manual

Page 9: Table 2 : usb interface wiring

Advertising
background image

ACR38x – Reference Manual

[email protected]

Version 6.02

www.acs.com.hk

Page 9 of 40

6.0. USB Interface

6.1. Communication Parameters

The ACR38x is connected to a computer through USB as specified in the USB Specification 2.0. The

ACR38x is working in full speed mode, i.e. 12 Mbps.

Pin

Signal

Function

1

V

BUS

+5 V power supply for the reader

2

D-

Differential signal transmits data between ACR38x and PC

3

D+

Differential signal transmits data between ACR38x and PC

4

GND

Reference voltage level for power supply

Table 2: USB Interface Wiring


Note:
In order for the ACR38x to function properly through USB interface, either ACS PC/SC driver

has to be installed.

6.2. Endpoints

The ACR38x uses the following endpoints to communicate with the host computer:

Control Endpoint For setup and control purpose

Bulk OUT

For command to be sent from host to ACR38x
(data packet size is 64 bytes)

Bulk IN

For response to be sent from ACR38x to host
(data packet size is 64 bytes)

Interrupt IN

For card status message to sent from ACR38x to host
(data packet size is 8 bytes)