Power_off, Exchange_tpdu_t0 – ACS ACR38 SAM Smart Card Reader User Manual

Page 18

Advertising
background image

ACR38x – Reference Manual

[email protected]

Version 6.02

www.acs.com.hk

Page 18 of 40

Response data format

Header Status

Data length

ATR

LEN

01h

Where:

ATR

Answer-To-Reset as transmitted by the card according to ISO 7816-3.


Note:
The ATR is only returned in the reader response if the communication protocol of the card is

compatible with the ACR38x, i.e., if the card can be processed by the reader. Otherwise, ACR38x

returns an error status and deactivates the smart card interface.

9.2.1.3. POWER_OFF

This command powers off the card inserted in the ACR38x.
Command Format

Header Instruction

Data length

LEN

01h

81h

00h

00h


Response Data Format

Header Status

Data length

LEN

01h

9.2.1.4. EXCHANGE_TPDU_T0

This command exchanges an APDU command/response pair between the card inserted in the

ACR38x and the host computer.
Command Format

Header Instruction

Data length LEN

Data

MSB

LSB

T0 TPDU

01h

A0h

Where:

LEN

Length of APDU command data, N.

Data

T0 TPDU to be sent to the card.

Case 1: CLA INS P1 P2
Case 2: CLA INS P1 P2 Le
Case 3: CLA INS P1 P2 Lc Data
Case 4: Not supported. The driver/application should break case 4 command

into case 3 + case 2 commands.

Advertising