Btu specifications, Front i/o board, Fan module – Dell PowerEdge C410x User Manual

Page 12: Power supply

Advertising
background image

10

BTU Specifications

2. Front I/O Board

Power Button

Power button with LED

Service ID
Button

Service ID button with LED

LED
Functionality

- Power LED indicates current system power ON/OFF/Fail status.

- Service ID LED indicates system in service.

- System Status LED indicates current system status (for example, FAN fail).

Temperature
Sensor

Indicates system ambient temperature for FAN speed control usage.

3. FAN Module

FAN

Size: 92 mm x 38 mm

Hot Plug,
Redundant

7+1 Redundancy

Hot Swappable Fans

4. Power Supply

PSU Module

1400W * 4 PSUs

Input Voltage

200-240VAC

Type (AC/DC)

AC

Redundancy

N+1 redundancy required for total chassis load.

Specification

Value

Power Supply Voltage Range

200V - 240Vac

Power Supply

Four

Power Supply BTU

14334.6 BTU/hr

Power Supply: Power (W)

4200

Advertising