Installation and configuration, Unpack your system – Dell PowerEdge C410x User Manual

Page 5

Advertising
background image

3

CAUTION: To reduce the risk of electric shock, this system should only be serviced by

qualified service personnel.

Restricted Access Location

The Dell PowerEdge C410X system is intended for installation only in restricted access locations as defined in
Cl. 1.2.7.3 of IEC 60950-1: 2001.
1.2.7.3 RESTRICTED ACCESS LOCATION: A location for equipment where both of the following paragraphs
apply:

Access can only be gained by SERVICE PERSONS or by USERS who have been instructed about the
reasons for the restrictions applied to the location and about any precautions that shall be taken.

Access is through the use of a TOOL or lock and key, or other means of security, and is controlled by
the authority responsible for the location.

CAUTION: To prevent the system PSUs from overloading and to ensure the optimum system

performance and stability, always follow the table below for PSU and GPGPU configuration.

Minimum PSU Quantity

Maximum GPGPU Quantity

1 4

2

8

3

16

The fourth PSU is redundant.

Installation and Configuration

WARNING: Before performing the following procedure, review the safety instructions that
came with the system.

Unpack your system

Unpack your system and check that the following items are included.

 One Dell PowerEdge C410X system chassis
 Dell PowerEdge C410x Getting Started Guide
 Safety, Environmental, and Regulatory Information (SERI)
 Warranty and Support Information (WSI) or End User License Agreement (EULA)

Contact Dell if some items are missing or appear damaged.

Advertising