Dell PowerVault MD3000i User Manual

Page 15

Advertising
background image

Getting Started With Your System

13

Environmental (Battery Backup Unit [BBU])

NOTE:

For additional information about environmental measurements for specific

system configurations, see

dell.com/environmental_datasheets

Maximum input power

• +12 VDC +/–5% at 1 A
• +3.3 VDC +/–5% at 150 mA
• Operating temperature range: 5° to

35°C (41° to 95°F)

Regulated output voltage from BBU

• +2.5 VDC +/–3% at 20 mA to 120 mA
• Operating temperature range: 5° to

45°C (41° to 113°F)

Minimum retention time (life
expectancy)

72 hours for 512-MB DDR-I DIMM,
2.5 V at 120 mA

Working temperature range (dry bulb)

• 5° to 35°C (41° to 95°F)
• Maximum dry bulb temperature

derated by 3.3°C (37.9°F) per 1000 m
(3281 ft) above 500 m (1640 ft)

Working relative humidity range

5% to 90% noncondensing

Storage temperature range (dry bulb)

• –10° to 45°C (14° to 113°F) for

3 months maximum

• Maximum dry bulb temperature

derated by 3.3°C (37.9°F, guaranteed)
per 1000 m (3281 ft) above 500 m
(1640 ft)

Transit temperature range (dry bulb)

–20° to 60°C (–4° to 140°F) for 1 week
maximum

Storage and transit humidity range

5% to 95% relative humidity

Storage and transit maximum
temperature gradient

1°C (33.8°F) per minute to a maximum
of 20°C (68°F) per hour

Storage and transit maximum humidity
gradient

30% relative humidity per hour

Advertising