Dell PowerEdge C6100 User Manual

Page 16

Advertising
background image

14

Getting Started With Your System

Environmental

NOTE:

For additional information about environmental measurements for specific

system configurations, see

www.dell.com/environmental_datasheets.

Temperature

Operating

10° to 35°C (50° to 95°F) with a maximum
temperature gradation of 10°C per hour

NOTE:

For altitudes above 2950 feet,

the maximum operating temperature
is derated 1ºF/550 ft.

Storage

–40° to 65°C (–40° to 149°F) with
a maximum temperature gradation
of 20°C per hour

Relative humidity

Operating

20% to 80% (noncondensing) with
a maximum humidity gradation
of 10% per hour

Storage

5% to 90% (noncondensing)

Maximum vibration

Operating

0.26 Grms at 5–350 Hz

Storage

1.54 Grms at 10–250 Hz for 15 min

Maximum shock

Operating

One shock pulse in the positive z axis
(one pulse on each side of the system) of
31 G for 2.6 ms in the operational orientation

Storage

Six consecutively executed shock pulses in
the positive and negative x, y, and z axes
(one pulse on each side of the system) of
71 G for up to 2 ms

Six consecutively executed shock pulses
in the positive and negative x, y, and z axes
(one pulse on each side of the system) of
27 G faired square wave pulse with
velocity change at 235 inches/second
(597 centimeters/second)

Advertising