9 power-up and test procedure, Installation – American Magnetics 05100PS-430-601 High Stability Integrated Power Supply System User Manual

Page 38

Advertising
background image

20

Rev.

3

Installation

Power-Up Procedure

overcome the 5 Vdc bias. Once the bias is achieved, the series resistance is

minimal and the Model 601 appears as a short-circuit. It is not possible to

decrease the stability setting to remove the integration time, since once

the 5 Vdc bias is achieved, the load is a short-circuit and the system will

become unstable.

However, when operating with a superconducting magnet in the circuit,

the integration gain of the Model 430 Programmer will be adequate to

quickly “bias” the Model 601 and achieve a proper current ramping profile.

The only time the “integration time” is long is when an energy absorber is

used, and the load is a short circuit.

2.9 Power-Up and Test Procedure

It is important to verify that the magnet system has been properly

connected before the superconducting magnet is energized. This is

especially recommended if the system is to be controlled via a computer

since this setup will allow software debugging without the potential for

damage to the magnet. The following procedures will assist the user in the

verifying key system components.

1. Using the appropriate diagram from section 2.5 as a guide, verify

all system components are connected as shown. If there is any

doubt as to the correct connection of a component, contact an AMI

Technical Support Representative. The user may be required to

properly make a few connections between the various system

components which were disconnected to facilitate packing and

shipping.

2. Temporarily place a short across the magnet current terminals.

Often this is most easily accomplished by unfastening the heavy

cables from the magnet current leads and fastening them together.

1

This will allow rudimentary power supply checks without

energizing the superconducting magnet.

3. Energize the Model 430 Programmer by placing the power switch

in the

I (ON) position.

Note

Ensure the Model 601 energy absorber power adapter is properly

connected to the energy absorber and the AC power receptacle.

1. If the system shipped with CamLoc quick-disconnect connectors, they may be quickly dis-

connected from the magnet leads and connected together.

Advertising