Issue
10.04.A

XTnano – Version 10.04 – Operating Manual

EVS Broadcast Equipment SA – January 2011


10

Function Key

Use

F3: 3 Remotes

N/A.

F4: 4 Remotes

N/A.

F5: Char. On/Off Enables or disables the on-screen display (Timecode, Clip

ID…) on the output monitors.

F6: Exit

Exits the Multicam software and returns to the EVS Menu.

F7: Clear all
clips

Clears all clips. All clips will be lost. A confirmation of this
command is required.

For more information to this action, refer to the section 0 ‘How
to Clear All Unprotected Clips’
, on page 36.

Note: This command is not similar to the Clear Video Disks
from the Maintenance menu. If you wish to refresh completely

the server, that is to clear all clips including the protected
ones, you need to use Clear Video Disks rather than Clear all
clips
.

F8: Stop Record Stops the record. The REC key will go off and the F8 function

key is now used to restart the record.

F9: Fill playlist

«Dump» feature which allows all clips to be «dumped» at the
end of the current playlist. This allows the operator to save all
material to tape, as a backup feature after a show is complete.
You can select in the Setup menu which camera angles have to

be included in the Fill Play-List function.

Make sure the playlist you have selected is an empty one. This
function will append the clips at the end of an existing playlist.

Important

In order to guarantee the validity of data and clips previously saved, it is
advised to properly exit the application by pressing ALT + Q and ENTER
from the keyboard, or F6 and then ENTER from the Remote Panel. DO
NOT TURN OFF THE SYSTEM WHILE THE APPLICATION IS RUNNING.