Varid configuration file, Uniqueness, Length – EVS XSnano Version 11.01 - November 2012 Configuration Manual User Manual
Page 131

VarID Configuration File
The VarID parameters are defined in a configuration file. This file, named varid.ini, is
located in the C:\LSMCE\DATA directory.
The file has the following syntax:
;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
; VARID settings
;------------------------------
;Parameter values and [default]
;
; Uniqueness= [Local] or Global
; Length= [32] or 8
; Format= [ASCII] or Binary
; Visibility= [], 1..29,*
; default= empty is converted to local XT Net
number
; * for all XNet
;
;------------------------------
Uniqueness=Local
Length=32
Format=ASCII
1=
2=
3=
4=
5=
6=
;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
Uniqueness
Description
This field is not relevant on this type of server.
Value
The value is forced to 'Local', which means that the VarID is
unique at the server level.
Length
Description
Specifies whether the VarID has a fixed length of 8 bytes or a
variable length of 32 bytes.
Values
•
8, fixed length.
•
32, variable length.
Default value
32
121
3. Multicam Configuration
EVS Broadcast Equipment S.A. - November 2012
Issue 11.01.B