5 setup – Soft dB Opus Suite Intensity Module User Manual

Page 11

Advertising
background image

9

5 Setup

Input Setup

These controls allow selecting the microphone spacer, input channel, the input

type and the input range from drop down lists.

Record Setup

These controls allow selecting the record directory, to write a custom file prefix

to the file names and to select the auto-save mode that automatically records

measurements when they end. Their names are automatically incremented in

the record directory.

Spectrum Range

This control is used to define the spectrum range. This range will be used to

compute the global level and to restrict the spectrum display to this specific

range. This tool is commonly used to restrict the spectrum range to the

specifications associated to a specific microphone spacer as described in the

following table:

Microphone Spacer

Error < |2 dB|

Error < |4 dB|

50 mm

60 Hz – 1.8 kHz

20 Hz – 2 kHz

12 mm

100 Hz – 10 kHz*

63 Hz – 10 kHz*

8 mm

200 Hz – 10 kHz

125 Hz – 10 kHz

Advertising