Dip switches setting – V-Tech DT597 Manual User Manual

Page 10

Advertising
background image

DIP Switches Setting

The DIP switch is designed to set the code

for door station and monitor, there are two

states for each DIP switch, please refer to

the sketch map.

ON(1)

=

OFF(0)

=

ON

ON

Total 2 bits can be configured, bit-1 and bit-2 are used to assign ID code for door sta-

tion.The switches can be modified either before or after installation.

There are 6 bits in total. The DIP switches are used to configure the user code

for Monitors.

Bit-6 is an video impedance match switch, which have to be set to ON if match

the impedance, otherwise set to OFF.

Bit-1~Bit-5 are used to set user code, for DT597 door station, the user code

should be set to 0~15.

Please refer to the following settings:

Door station DIP setting

Indoor monitor DIP setting

Bit state

Descriptions

Default setting, ID = 0(00), set to the first Door Station.

ID = 1(10), set to the second Door Station.

ID = 2(01), set to the third Door Station.

ID = 3(11), set to the fourth Door Station.

1 2

ON

1 2

ON

1 2

ON

1 2

ON

-10-

Advertising