4 technical data, General data, Supply voltage (us) – VEGA FL SWITCH SFN… User Manual

Page 3: 4technical data

Advertising
background image

FL SWITCH SFN…

2732_en_D

PHOENIX CONTACT

3

4

Technical Data

Security frame for SFN switch and patch fields, red

FL PLUG GUARD, RD

2891712

20

Security frame for SFN switch and patch fields, white

FL PLUG GUARD, WH

2891819

20

Security frame for SFN switch and patch fields

FL PORT GUARD

2891220

20

Security frame for SFN switch and patch fields

FL PLUG GUARD KEY

2891327

1

Security element for FL CAT patch

FL PATCH SAFE CLIP

2891246

20

General Data

Function

Switch/repeater; conforms to standard IEEE 802.3

Latency of the communication processor

8 µs plus frame time

Housing dimensions (width x height x depth)

5-port switch, without connectors

8-port switch, without connectors

30 x 120 x 100 mm (without COMBICON/without fiber optics)

50 x 120 x 100 mm (without COMBICON/without fiber optics)

Operating temperature

FL SWITCH SFN …TX… and FL SWITCH SFN 6GT/2LX-20

FL SWITCH SFN 8GT, FL SWITCH SFN 6GT/2SX,

FL SWITCH SFN 7GT/SX

FL SWITCH SFN 6GT/2LX

0 to 60°C

-25 to 75°C

-25 to 60°C

Storage temperature

FL SWITCH SFN…TX… switches

FL SWITCH SFN…GT… switches (not FL SWITCH SFN 6GT/2LX-20)

FL SWITCH SFN 6GT/2LX-20

-20 to 70°C

-35 to 85°C

-20 to 70°C

Degree of protection

IP20, DIN 40050, IEC 60529

Protection class

Class 3 VDE 0106; IEC 60536

Humidity (operation and storage)

5% to 95%, no condensation

Air pressure (operation)

86 kPa to 108 kPa, 1500 m above sea level

Air pressure (storage)

66 kPa to 108 kPa, 3500 m above sea level

Mounting

NS 35 (EN 60715)

Preferred mounting position

Perpendicular to a standard DIN rail

Connection to protective ground

Snapped onto a grounded DIN rail

Weight, without connectors

5-port switch

8-port switch

265 g

440 g

Accessories

Description

Type

Order No.

Pcs./Pkt.

Supply Voltage (US)

Connection type

Removable COMBICON, screw-cage connector

Wire size (solid/stranded/AWG)

0.2 to 2.5 mm² / 0.2 to 2.5 mm² / 24 to 12 AWG

Recommended PE wire size

2.5 mm²

Nominal power supply

12 or 24 V DC

Permissible ripple

3.6 V

pp

within the permissible voltage range

Permissible voltage range

9 V DC to 30.2 V DC

Test voltage

500 V DC for one minute

Protection against polarity reversal

Present