he version with horn antenna is particularly suitable for

measurement of virtually all bulk solids in small silos and vessels.

l

T

he version with parabolic antenna is particularly suitable for large

silos and vessels with up to 70 m (76 yd) measuring distance and
for measurement of solids with low dielectric constant.

VEGAPULS

68

is also suitable for applications in liquids.

T

he antenna of the radar sensor emits short radar pulses with a

duration of approx. 1 ns. These pulses are reflected by the product
and received by the antenna as echoes. The running time of the radar
pulses from emission to reception is proportional to the distance and
hence to the level. The determined level is converted into an
appropriate output signal and outputted as measured value.

F

our-wire electronics with separate power supply.

T

he supply voltage range can differ depending on the instrument

version.

T

he data for power supply are specified in chapter "Technical data".

M

easured value transmission is carried out via the 4 … 20 mA/HART

output separate from power supply.

T

he background lighting of the indicating and adjustment module is

powered by the sensor. A certain level of operating voltage is required
for this. You can find the exact voltage specifications in chapter
"

Technical data".

3.3 Operation

VEGAPULS

68

can be adjusted with different adjustment media:

l

with indicating and adjustment module

l

with the suitable VEGA DTM in conjunction with an adjustment
software according to the FDT/DTM standard, e.g. PACTware and
PC

l

with manufacturer-specific adjustment programs AMS™ or PDM

l

W

ith a HART handheld

T

he entered parameters are generally saved in VEGAPULS 68,

optionally also in the indicating and adjustment module or in
PACT

ware.

3.4 Packaging, transport and storage

Y

our instrument was protected by packaging during transport. Its

capacity to handle normal loads during transport is assured by a test
according to DIN EN 24180.

T

he packaging of standard instruments consists of environment-

friendly, recyclable cardboard. For special versions, PE foam or PE foil
is also used. Dispose of the packaging material via specialised
recycling companies.