3 Product description

PLICSMOBILE T61 • External GSM/GPRS radio unit

37700-EN-130228

sensors. Due to the large operating voltage range and the integrated

power saving functions, a mains-independent power supply via bat-

tery or solar cells is possible. Typical applications are measured value

transmission from mobile vessels, battery-operated level measure-

ment and deep well measurement.
The measured value and message transmission can be optionally

carried out via e-mail or SMS. Furthermore the measured values can

be transitted via http to the visualisation software WEB-VV. The use of

the PLICSMOBILE T61 is particularly suitable for inventory manage-

ment, VMI (Vendor Managed Inventory) and remote enquiry.

The external radio unit PLICSMOBILE T61 can be connected to any

4 … 20 mA HART two-wire sensor of the plics

®

series. The prereq-

uisite for this is always the version in the single chamber housing

with I²C interface for connection of a VEGADIS 61. The measured

value detected by the sensor is passed on via the I²C interface to the

PLICSMOBILE T61.
The transmission of measured values, event messages and diagnos-

tic information to the user is carried out via the GSM/GPRS network.

Thanks to quadband technology, the device can be used virtually

anywhere in the world. There is also the option of accessing the con-

nected sensor via remote parameter adjustment.

Power is supplied via a standard low voltage source (external power

supply unit/battery/accumulator/solar module) or via an battery/ac-

cumulator pack integrated in the battery chamber (optional). You can

find detailed specifications on the power supply in chapter "Technical

data".
As an option, the PLICSMOBILE T61 can also provide power to the

connected sensor.

3.3 Operation

The adjustment is made via PACTware and the respective DTM by

using the integrated USB connection.

3.4 Packaging, transport and storage

Your instrument was protected by packaging during transport. Its

capacity to handle normal loads during transport is assured by a test

following ISO 4180.
The packaging of standard instruments consists of environment-

friendly, recyclable cardboard. For special versions, PE foam or PE

foil is also used. Dispose of the packaging material via specialised

recycling companies.

Transport must be carried out under consideration of the notes on the

transport packaging. Nonobservance of these instructions can cause

damage to the device.

The delivery must be checked for completeness and possible transit

damage immediately at receipt. Ascertained transit damage or con-

cealed defects must be appropriately dealt with.

Functional principle

Voltage supply

Packaging

Transport

Transport inspection