linearization is necessary for all vessels in which the vessel volume

does not increase linearly with the level - e. g. with a cylindrical or
spherical tank - and the indication or output of the volume is required.
C

orresponding linearization curves are preprogrammed for these

vessels. They represent the correlation between the level percentage
and vessel volume. By activating the appropriate curve, the volume
percentage of the vessel is displayed correctly. If the volume should
not be displayed in percent but e.g. in l or kg, a scaling can be also set
in the menu item "Display".

L

inearisation curve

linear

E

nter the requested parameter via the appropriate keys, save your

settings and jump to the next menu item with the [->] key.

T

his function enables reading out parameter adjustment data as well

as writing parameter adjustment data into the sensor via the indicating
and adjustment module. A description of the function is available in the
operating instructions manual "Indicating and adjustment module".

T

he following data are read out or written with this function:

l

M

easured value presentation

l

A

djustment

l

D

amping

l

L

inearisation curve

l

S

ensor-TAG

l

D

isplayed value

l

D

isplay unit

l

S

caling

l

C

urrent output

l

U

nit of measurement

l

L

anguage

T

he following safety-relevant data are not read out or written:

l

SIL

l

HART

mode

l

PIN

l

A

pplication

C

opy sensor data

C

opy sensor data?

Basic adjustment
I

f the "Reset" (sensor-specific basic adjustment) is carried out, the

sensor resets the values of the following menu items to the reset
values (see chart):

Linearisation curve

Copy sensor data

Reset

VEGABAR

52 • 4 … 20

mA/HART - climate compensated

31

6 S

et up with the indicating and adjustment module PLICSCOM

35075

-

EN

-081209