70cru04pbf, Vishay high power products, Ultrafast rectifier, 2 x 35 a fred pt – Vishay 70CRU04PbF User Manual

Page 4

Advertising
background image

www.vishay.com

For technical questions, contact: [email protected]

Document Number: 94510

4

Revision: 21-Jul-08

70CRU04PbF

Vishay High Power Products

Ultrafast Rectifier,

2 x 35 A FRED Pt

TM

Fig. 5 - Maximum Allowable Case Temperature vs.

Average Forward Current

Fig. 6 - Forward Power Loss Characteristics

Fig. 7 - Typical Reverse Recovery Time vs. dI

F

/dt

Fig. 8 - Typical Stored Charge vs. dI

F

/dt

Note

(1)

Formula used: T

C

= T

J

- (Pd + Pd

REV

) x R

thJC

;

Pd = Forward power loss = I

F(AV)

x V

FM

at (I

F(AV)

/D) (see fig. 6);

Pd

REV

= Inverse power loss = V

R1

x I

R

(1 - D); I

R

at V

R1

= Rated V

R

Average Forward Current - I

F(AV)

(A)

Allowable Case Temperature (°C)

100

110

120

130

140

150

160

170

180

0

5

10

15

20

25

30

35

40

DC

Square wave (D = 0.50)
Rated Vr applied

see note (1)

Average Power Loss ( Watts )

Average Forward Current - I

F(AV)

(A)

0

5

10

15

20

25

30

35

40

0

5

10

15

20

25

30

35

RMS Limit

D = 0.01
D = 0.02
D = 0.05
D = 0.10
D = 0.20
D = 0.50
DC

trr ( ns )

di

F

/dt (A/μs )

50

60

70

80

90

100

110

120

130

140

150

100

1000

Tj = 125˚C

Tj = 25˚C

If = 35A
Vrr = 200V

Qrr ( nC )

di

F

/dt (A/μs )

0

500

1000

1500

2000

2500

100

1000

Tj = 125˚C

Tj = 25˚C

If = 35A
Vrr = 200V

Advertising