Technical data, Rating definitions and conditions – Milton CAT G3412 375 kW Continuous 375 kW 60 Hz Spec Sheet User Manual

Page 3

Advertising
background image

S T A N D B Y

3 7 5

e k W

C O N T I N U O U S

3 7 5

e k W

6 0 H z

3

TECHNICAL DATA

Open Generator Set —

Standby

Continuous

1800 rpm/60 Hz/480 Volts

DM5443

DM5444

Package Performance

Power rating

ekW

375

375

Power rating @ 0.8 PF

kVA

469

469

Aftercooler temperature

Deg C

Deg F

54

130

54

130

Fuel Consumption

100% load with fan

N•m

3

/hr

scf/hr

137

5141

137

5141

75% load with fan

N•m

3

/hr

scf/hr

108

4062

108

4062

50% load with fan

N•m

3

/hr

scf/hr

78

2942

78

2942

Cooling System

Ambient air temperature*

Deg C

Deg F

40

105

40

105

Air flow restriction (system)

kPa

in water

0.12

0.5

0.12

0.5

Air flow (maximum @ rated speed for

standard radiator arrangement)

m

3

/min

cfm

1430

50,491

1429

50,491

Engine coolant capacity with radiator

L

Gal

140

37

140

37

Jacket water outlet temperature

Deg C

Deg F

99

210

99

210

Exhaust System

Combustion air inlet flow rate

N•m

3

/min

scfm

36

1307

36

1307

Exhaust gas stack temperature

Deg C

Deg F

371

700

371

700

Exhaust gas flow rate

N•m

3

/min

cfm

37

3125

37

3125

Exhaust flange size (internal diameter)

mm

in

203

8

203

8

Exhaust system backpressure

(maximum allowable)

kPa

in water

6.7

27

6.7

27

Heat Rejection

Low Heat Value (LHV) fuel input

kW

Btu/min

1386

78,809

1386

78,809

Heat rejection to jacket water

(includes oil cooler)

kW

Btu/min

457

25,983

457

25,983

Total heat rejection to exhaust (LHV to 25° C)

kW

Btu/min

334

19,001

334

19,001

Heat rejection to exhaust (LHV to 120° C)

kW

Btu/min

220

9665

220

9665

Heat rejection to A/C

kW

Btu/min

64

3659

64

3659

Heat rejection to atmosphere from engine

kW

Btu/min

55

3152

55

3152

Heat rejection to atmosphere from generator

kW

Btu/min

29

1660

29

1660

Generator

Motor starting capability @ 30% voltage dip**

kVA

928

928

Frame

592

592

Temperature rise

Deg C

130

105

Emissions***

NOx

g/bhp-hr

2

2

CO g/bhp-hr

1.9

1.9

HC (total)

g/bhp-hr

5.4

5.4

HC (non-methane)

g/bhp-hr

0.81

0.81

Exhaust O

2

(dry)

%

8.7

8.7

**

*Ambient capability at 200 m (660 ft) above sea level. For ambient capability at other altitudes, consult your Caterpillar dealer.

*

**Assumes synchronous driver

***Emissions data measurement is consistent with those described in EPA CFR 40 PART 89 SUBPART D and ISO 8178-1 for

measuring HC, CO, CO

2

and NOx. Data shown is based on steady state engine operating conditions of 77° F, 28.43 inches HG

and fuel having a LHV of 920 BTU per cubic foot at 30.00 inches HG absolute and 32° F. Not to exceed emission data shown is
subject to instrumentation, measurement, facility and engine fuel system adjustments.

Standby — Output available with varying load for the
duration of the interruption of the normal source power.

Continuous — Output available without varying load
for an unlimited time.

Ratings are based on ISO3046/1 standard reference
conditions of 25° C (77° F) and 100 kPa (29.61 in Hg).

Ratings are based on pipeline natural gas having a LHV
(low heat value) of 36.2 mJ/N•m

3

(920 Btu/cu ft). Variations

in altitude, temperature, and gas composition from standard
conditions or the use of a three way catalyst may require
a reduction in engine horsepower.

RATING DEFINITIONS AND CONDITIONS

Advertising