Velleman VDPDP152 User Manual

Page 4

Advertising
background image

VDPDP152_v3

VELLEMAN

4


FUNCTION = FUNCTIE = FONCTION

1 2 3 4 5 6 7 8 9 10
any one of the DIP switches 1-9 is ON, DMX parallel 1
all the DIP switches 1-9 are OFF, auto parallel
any one of the DIP switches 1-9 is ON, DMX

0

all the DIP switches 1-9 are OFF, auto

DMX ADDRESS = DMX ADRES = ADRESSE DMX

1 2 3 4 5 6 7 8 9 start.

address

1 0 0 0 0 0 0 0 0

1

0 1 0 0 0 0 0 0 0

2

1 1 0 0 0 0 0 0 0

3

0 0 1 0 0 0 0 0 0

4

1 0 1 0 0 0 0 0 0

5

1 1 1 1 1 1 1 1 1

512


The device can perform several functions, depending on the setting of the last DIP switch (n° 10). See table above

for the different settings.
When all connections are made, connect the device to the mains power and turn on the circuit breaker. Adjust the

output of the analogue controller to adjust the corresponding load on the selected channel.

Note that each channel has an output LED to show the actual status of the channel.

6. Fuse


Do not try to repair the device. You can only open the housing to replace a blown fuse with an identical one.

Unscrew the cover of the fuse holder with a screwdriver, remove the old fuse, insert the new one and close the fuse
compartment again. Order spare parts from your local dealer.

7. Cleaning and Maintenance


1. All screws for installing the devices or parts of the device have to be screwed down tight and must not be

corroded.

2. Neither the housing nor the mounting supports should not be modified or tampered with.

3. The electric power supply cables must be undamaged. Have the device installed by a qualified technician.
4. Disconnect the device from the mains prior to maintenance activities.

5. Wipe the device regularly with a moist cloth. Do not use alcohol or solvents.
6. Entrust a qualified technician with the maintenance of this device. Contact your dealer for spare parts if

necessary.

8. Technical Specifications


Power Supply

230Vac / 50Hz

Number of channels

4

Maximum total load

max. 3520W

Maximum total current

max. 16A

Maximum load per channel

1100W

Output connections

4 x SCHUKO socket

Fig. 3

Advertising