In case of the 5-channel VDPLP64xx, you will have to set the start address of the first unit to
001 (CH1~4), the second unit to 006 (1 + 5) (CH5~8), the third to 011 (6 + 5) (CH9~12), and
so on.

Use the UP- [2] or DOWN-button [3] to select a DMX starting address. After selecting, it takes
±3s before the address becomes active. The display shows alternately the address and “d”.

The selected address is automatically stored in memory.

While a DMX-signal is received, a LED on the lower right will be on.

The unit receives DMX values in a packet of 5 channels and mirrors this data on the DMX output
[6]:

DMX channel

Value Range Function

CH1

000-255

red (Out1 level)

CH2

000-255

green (Out2 level)

CH3

000-255

blue (Out3 level)

CH4

0-100

Dimmer

CH5

0-100

Shutter

d) Display ON/OFF

When the display does not detect user inputs for ±25s, it will automatically switch off.

To switch it on again, press any button (settings are not affected).

e) Key lock

Pressing and holding the MODE-button [1] for more than 3s will lock all buttons ([1], [2] and
[3]). The display shows alternately the current mode and “LOC”.

Press and hold the MODE-button [1] again for more than 3s to unlock the buttons.

f) Switch-on status

The device always returns to the mode/status it was in when it was switched off. However, all
DMX values are cleared at power-off.

g) DMX signal loss

The device will retain the status it was in before signal loss.

8.

Cleaning and maintenance

1. All screws should be tight and free of corrosion.
2. The housing, the lenses, the mounting supports and the installation location (e.g. ceiling,

suspension, trussing) should not be deformed, modified or tampered with e.g. do not drill extra
holes in mounting supports, do not change the location of the connections …

3. Mechanically moving parts must not show any signs of wear and tear.
4. The electric power supply cables must not show any damage. Have a qualified technician

maintain the device.

5. Disconnect the device from the mains prior to maintenance activities.
6. Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents.
7. There are no user-serviceable parts.
8. Contact your dealer for spare parts if necessary.

9.

Technical specifications

VDPLP64B2

VDPLP64C2

VDPLP64B3

VDPLP64C3

colour

black

chrome

black

chrome

power supply

90-250VAC / 50-60Hz (switching power mode)

power consumption

20W

44W

DMX channels

5

number of LEDs

177 (36 R, 83 G, 58 B)

39 x 1W (9 R, 18 G, 12 B) - Edison

beam angle

20°

dimensions

Ø186 x 252mm

weight

1.5kg

2kg