Continuous measurement/max. & min. measurement [C]

In continuous mode the meter will measure the distance every 0.5s

while displaying minimum and maximum measured values [9].

The minimum measured value is shown on the first line of the display

[10], the maximum value on the second line [11]. The last measured

value is indicated on the bottom line [12].

To start continuous measurement, press the measuring mode button

[d] until the max./min. indications [9] are shown. Measurement starts

immediately.

Slowly move the laser beam over the surface tor determine the

minimum and maximum distance towards it (see illustration C).

To stop measuring, press the ON/measuring button [a] or clear/OFF

button [j]. Note: measuring will automatically stop after 100

measurements.

Area measurement

Press the area/volume button [b]. The area icon

appears [4].

Press the ON/measuring button [a] to measure the first side of the

surface. The value appears in the first line [10].

Press the ON/measuring button [a] again to switch on the laser. Press

again to measure the second side of the surface. The value appears in

the second line [11].

The resulting area is calculated and displayed on the third line [12].

Volume measurement

Press the area/volume button [b] two times. The volume icon

appears [4].

Press the ON/measuring button [a] to measure the first side. The value

appears in the first line [10].

Press the ON/measuring button [a] again to switch on the laser. Press

again to measure the second side. The value appears in the second line

[11].

The area is calculated and displayed on the third line [12].

Press the ON/measuring button [a] again to switch on the laser. Press

again to measure the third side. The value appears in the second line

[11], the previous value moves to the first line [10].

The volume is calculated and displayed on the third line [12].

Indirect measurement – 2 measurements [D]

Press the indirect measurement button [c]. The 1st indirect

measurement icon

appears [4].

Press the ON/measuring button [a] to measure the first distance

(highest point, see illustration D). The value appears in the first line

[10].

Press the ON/measuring button [a] again to switch on the laser. Press

again to measure the second distance. The value appears in the second

Advertising