AC/DC VOLTAGE MEASUREMENT
• Connect the red test lead to the "V Ω °C/°F" jack [10] and the black lead

to the "COM" jack [9].

• Set the rotary function switch [3] in the

position.

• Use the mode button [5] to choose between AC and DC voltage.

• Connect the test leads parallel to the source being measured.

• Read the voltage value on the LCD display [8] along with the polarity of

the red lead connection.

AC CURRENT MEASUREMENT
• Make sure no test leads are connected to the “V Ω °C/°F” [10] or “COM”

[9] jacks.

• Set the rotary switch [3] in the desired range (40A, 400A or 1000A). If

the current to be measured is unknown beforehand, set the range switch
in the highest range position and then reduce gradually until the ideal

resolution is obtained.

• Press the trigger [2] to open the jaws [1] of the clamp. Enclose a single

conductor within the clamp and release the trigger [2]. Enclosing

multiple conductors at the same time will result in faulty measurements.

• Read the current value on the LCD display.
RESISTANCE, AUDIBLE CONTINUITY, DIODE and CAPACITY TEST
• Connect the red test lead to the "V Ω °C/°F" jack [10] and the black lead

to the "COM" jack [9].

• Set the rotary switch [3] in the "

" position.

• For resistance test and continuity test, press the mode button [5] until

the “Ω” symbol appears in the display. Connect the test leads to the

resistor to be measured and read the value in the LCD display.
Disconnect one side of the device under test to avoid interference from
the rest of the circuit. When the resistance is <100Ω, a continuity buzzer

will sound.

• For diode measurements, press the mode button [5] until the "

"

symbol appears in the display. When the diode passes the test, indicated
forward voltage will be 0.4~0.7V while reverse voltage will indicate “OL”.

When the diode is short circuited, both readings will be ±0mV; when
open, both measurements will shown “OL”.

Notes:

forward DC current: ±0.3mA

open circuit voltage: ±1.5V

• For capacity measurements, press the mode button [5] until “F” is shown

in the display. Warning: disconnect power to the device under test

(including batteries!) and discharge all capacitors before measuring
capacitance. Connect the test leads to the capacitor to be measured and
read the value in the LCD display.

FREQUENCY or % DUTY CYCLE measurement
• Connect the red test lead to the "V Ω °C/°F" jack [10] and the black lead

to the "COM" jack [9].

• Set the rotary switch [3] in the "Hz·%" position. Select Hz or % duty

with the Hz - % select button [6], the selection is indicated in the

display.

• Connect the test leads to the circuit under test and read the value in the

LCD display.

TEMPERATURE
• Set the rotary switch [3] in the "°C·°F" position. Select °C or °F with the

mode select button [5], the selection is indicated in the display.