Velleman HAA2890 User Manual

Page 5

Advertising
background image

SPECIFICATIONS

Operating Voltage:

12V DC Nominal; 11-15V DC
Operating Current:

60mA (quiescent) to 95mA (two relays active)
Operation Temperature:

-20

C to +70

C

Environmental Humidity:

5-95% relative humidity non-condensing
Working Environment & Ingress Protection:

Indoor or Outdoor, IP-55 Weatherproof
Number of Users:

1,000 (PINs and/or Cards)
Proximity Card:

Standard EM Card or Keyfob, 125Khz
Number of Visitor Codes:

50, programmable for one time or with the time limit
Timings for Code Entry and Card Reading:

10 seconds waiting for next digit entry

30 seconds waiting for code entry after card reading
The Timer:

1-99,999 Seconds (Over 24 Hours possible) Programmable Timer for O/P 1
Egress Button:

Programmable for Instant, Delay with Warning and/or Alarm

Momentary or Holding Contact for the Exit Delay
Output Contact Ratings:

Output Relay 1 – N.C. & N.O. dry contacts, 2A/24VDC Max.

Door Bell Relay – N.O. dry contact, 1A/24VDC Max.

Tamper Switch – N.C. dry contact, 50mA/24VDC Max. , Magnet Operated Reed Switch
Dimensions:

168.5(H) X 46.5(W) X 24(D)mm
Weight:

160g net
Housing:

ABS Plastic Box

Specifications are subject to change for modification without notice