Velleman DVM8838 User Manual

Page 4

Advertising
background image

DVM8838

00 (23/10/2008)

4

Velleman

®

• LCD display with backlight

• data-hold, auto power-off and lock-on function
• MIN, MAX, DIF and record functions

• adjustable emissivity

• high and low alarm
5.

Overview

Refer to the drawings on page 2 of this manual.
1 IR sensor

6

mode button

2 laser pointer beam

7

laser/backlight button

3 LCD display

8

measurement trigger

4 down button

9

grip

5 up button

10

battery cover


A hold indication

F

°C or °F indication

B measuring indication

G

high and low alarm indication

C emissivity indication and value

H

MAX, MIN, DIF, AVH, HAL and LAL value

D battery, lock and laser ON indication

I

indication for H

E backlight ON indication

J

current measurement value


K °C and °F switch

M

alarm set switch

L lock on/off switch

6.

Operation

• Hold the thermometer by the grip [9] and point the IR sensor [1] towards the surface of

which the temperature needs to be measured.

• Pull and hold the measurement trigger [8]. The LCD display [3] shows the current

temperature [J].

• During measurement, the word ‘SCAN[B] is visible in the LED display. When the

measurement stops (trigger [8] released), the word ‘HOLD[A] is shown. The last
measured value will remain on the display until the measurement trigger [8] is pulled
again, or when the thermometer powers-off automatically (after ± 7 seconds).

• Depending on the mode, the bottom of the screen shows the MAX, MIN, DIF, AVH, HAL and

LAL value. Use the mode button [6] to scroll through the modes of the device. The mode
[I] and corresponding value [H] are shown on the display.

EMS

Emissivity

(*)

MAX

Highest measured value

MIN

Lowest measured value

DIF

Difference between the highest and lowest measured value

AVG

Average value of the temperature

HAL

Higher alarm limit

LAL

Lower alarm limit

(*)

For more information on emissivity, refer to §7 Useful information.

• To set EMS, HAL or LAL, use the up [5] or down [4] button to adjust the value and press

the mode button [6] again to save the value and go to the next item. To cancel mode
selection, pull the measurement trigger [8]. Pushing the mode button [6] after setting the
lower alarm limit will start the set-up cycle again.