9

SOUND

Sound Level Measurement Range

A-weighting LO (low):

35 – 100dB

A-weighting HI (high):

65 – 130dB

C-weighting LO (low):

35 – 100dB

C-weighting HI (high):

65 – 130dB

resolution 0.1dB

Typical Frequency Range

30Hz to 10KHz

Frequency Weighting

A- & C-weighting

Time Weighting

fast

Maximum Hold

max. value does not change if the
increase in volume < 1.5dB / 3 min.

Accuracy

±3.5dB at 94dB, 1KHz sine wave

Microphone

electret condenser microphone

LIGHT

Measuring Range

20, 200, 2000, 20000Lux (20000Lux
reading x 10)

Overrange Indication

“1”

Accuracy

±5% of reading + 10 digits (calibrated
with standard incandescence lamp at a
colour temperature of 2856K)

Thermal sensitivity

±0.1°C

Photo detector

silicon photo diode with filter

HUMIDITY/TEMPERATURE

Humidity Measurement Range 25 to 95%RH
Temperature Range

-20°C to +50°C (-4°F to +122°F) with
built-in temperature sensor

-20 to +200°C (-4°F to +200°F) for
low range

-20 to +750°C (-4°F to +1400°F) for
high range

Resolution

0.1%RH, 0.1°C/0.1°F low range,
1°C/1°F high range

Accuracy (after calibration)
Humidity

±5%RH (at 25°C, 35 to 95%RH)

Humidity Sensor Response Time

±6 min.

Temperature

±3% rdg ±2°C (from –20°C to
+200°C)

Advertising