Velleman HAA2866 User Manual

Page 6

Advertising
background image

SPECIFICATIONS

Operating Voltage:

12V DC Nominal; 11-15V DC
Operating Current:

75mA (quiescent) to 140mA (three relays active)
Operation Temperature:

-20

C to +70

C

Environmental Humidity:

5-95% relative humidity non-condensing
Working Environment & Ingress Protection:

All weather, IP-55
Number of Users:

Output 1 – 1,000 (PINs and/or Cards) + 50 Duress Codes

Output 2 – 100 (PINs and/or Cards) + 10 Duress Codes

Output 3 – 100 (PINs and/or Cards) + 10 Duress Codes
Proximity Card:

Standard EM Card or Keyfob, 125Khz
Number of Visitor Codes:

50, programmable for one time or with the time limit
Timings for Code Entry and Card Reading:

10 seconds waiting for next digit entry

30 seconds waiting for code entry after card reading
The Timers:

Three 1-99,999 Seconds (Over 24 Hours possible) Independent Programmable Timers for O/P 1, 2
& 3
Egress Button:

Programmable for Instant, Delay with Warning and/or Alarm

Momentary or Holding Contact for the Exit Delay
Input Sensing Terminals:

a) Door position, b) Egress, c) O/P 1 inhibit
Output Control Terminals:

Transistor Open Collector 24VDC/100mA sink Max for the following outputs

a) Duress, b) Alarm, c) Key Active, d) Output 3, e) Inter-lock
Output Contact Ratings:

Output Relay 1 – N.C. & N.O. dry contacts, 5A/24VDC Max.

Output Relay 2 – N.C. & N.O. dry contacts, 1A/24VDC Max.

Door Bell Relay – N.O. dry contact, 1A/24VDC Max.

Tamper Switch – N.C. dry contact, 50mA/24VDC Max.
Dimensions:

129(H) X 83.5(W) X 41(D)mm
Weight:

220g net
Housing:

ABS Plastic box

Specifications are subject to change for modification without notice