8

LTD HEATER INSTALLATION

BE SURE POWER IS

DISCONNECTED AND LOCKED

OUT BEFORE INSTALLATION!

FAILURE TO DO SO MAY CAUSE

SERIOUS INJURY OR DEATH.

1. Place heater on the ground next

to the inlet of the centrifugal fan.
The LTD heater is designed to
mount upwind. Be sure airflow
decal is pointing towards the in-
let of the fan.

2. Bolt LTD mounting brackets to

each of the six holes in the
downstream angle ring of the
heater. Snug tighten bolts such
that they can still pivot with little
force applied. See chart for slots
to bolt through in bracket.

THESE INSTRUCTIONS ARE

FOR HEATER INSTALLATION

ON FAN UNITS WITH 230V

MOTORS.

Figure 1: Make sure the LTD Heater is positioned in the right direction.

INSTALLING THE LTD HEATER WITH LTD MOUNTING BRACKETS

IMPORTANT!

Note: Heater Direction

Slot

End

Middle

Fan Inlet Bolt Circle

31" to 35"

Less than 31"

3. Pivot brackets so they are nearly

radial from center of heater.
Stand behind heater and deter
mine which bolts on fan inlet
best line up with the brackets.
Remove the nuts from those

six(6) bolts and bolt the remain-
ing six(6) brackets to fan using
nuts removed. It may be neces-
sary to remount the fan grill
guard so mounting brackets will
seat properly. Slots to use for
fan mounting bolts are below.

Slot

End

Middle

Inner

Fan Inlet Bolt Circle

35"

31 3/4"

29"

Figure 2: The six(6) mounting brackets positioned on the LTD Heater.