Auto-vent installation installation – Grain Systems Bin Accessories PNEG-268 User Manual

Page 2

Advertising
background image

Page 2 of 2

PNEG-268

Auto-Vent Installation

Installation

8. If the roof sheet does not have a prepunched hole for the roof vent, a hole must be cut. The cut hole

should match the roof vent. The hole inside edge should be approximately 15" from the eave.

(See Figure 5.)

9. Place the three (3) foam strips on roof sheet, as shown in

Figure 4.

Position roof vent over foam

strips and bolt down using 5/16" x 3/4" bin bolts and 5/16" flange nuts. (NOTE: See instructions
below for lower two (2) bolts of vent.)

Figure 3

Figure 4

Figure 5

NOTE: Install bolts for these two (2) holes
with the bolt head and neoprene washer to
the underneath side of the roof sheet and the
5/16" flange nut against the vent hold down
angle. Caulk holes.