Drying time table…… and 1120 (continued), Drying time table – Grain Systems PNEG-1650 User Manual

Page 20

Advertising
background image

1. Drying Time Table

20

PNEG-1650 GSI Portable Drying Charts

Drying Time Table……..120 and 1120 (Continued)

Corn...Full Heat (Continuous Flow)

Wheat, Barley, Milo...Dry and Cool (Automatic Batch)

The above drying capacities are estimates based on drying principles, field results and computer
simulations. Variances may occur due to grain physiological factors (kernel size, chemical composition,
variety, maturity), excessive fines, weather conditions, etc.

190°F

210°F

230°F

Moisture

% Unload

Rate

Dry

Time

Capacity

Dry BPH

% Unload

Rate

Dry

Time

Capacity

Dry BPH

% Unload

Rate

Dry

Time

Capacity

Dry BPH

% In

% Out*

18

17

96

10

2689

19

17

57

17

1603

65

15

1832

20

17

42

23

1191

48

20

1361

54

18

1531

21

17

34

28

969

39

25

1107

44

22

1246

22

17

29

33

825

34

29

943

38

26

1061

23

17

26

38

720

29

34

822

33

30

925

24

17

23

43

636

26

38

727

29

34

817

25

17

20

49

565

23

43

646

26

38

727

26

17

18

55

504

20

48

576

23

43

649

27

17

16

61

451

18

54

515

21

48

580

28

17

14

68

403

16

60

461

18

53

519

29

17

13

76

362

15

67

413

17

59

465

30

17

12

85

325

13

74

371

15

66

418

31

17

10

94

293

12

82

335

13

73

376

32

17

9

104

265

11

91

303

12

81

341

33

17

9

115

241

10

100

275

11

89

310

34

17

8

125

220

9

110

252

10

97

283

35

17

7

136

203

8

119

232

9

106

261

*Represents the target moisture out of the dryer. Expected final moisture in the bin is…...15.0%

Drying table based on 100% meter roll speed of…...2814 BPH

140°F

155°F

175°F

Moisture

Dry

Min.

Time

Hrs

Cool

Min.

Capacity

Dry BPH

Dry

Min.

Time

Hrs

Cool

Min.

Capacity

Dry BPH

Dry

Min.

Time

Hrs

Cool

Min.

Capacity

Dry BPH

% In % Out

15

13

32

0.54

15

482

28

0.46

15

524

16

13

43

0.72

15

407

37

0.61

15

447

31

0.51

15

495

17

13

53

0.88

15

356

45

0.75

15

394

38

0.63

15

439

18

13

62

1.03

15

318

53

0.89

15

354

45

0.74

15

397

19

13

71

1.19

15

287

61

1.02

15

321

51

0.86

15

362

20

13

81

1.35

15

261

69

1.16

15

293

58

0.97

15

332

21

13

91

1.52

15

238

78

1.30

15

268

66

1.09

15

305

22

13

102

1.70

15

217

88

1.46

15

245

74

1.23

15

280

23

13

114

1.90

15

198

98

1.63

15

225

82

1.37

15

258

Drying table based on 100% meter roll speed of…...2814 BPH

Unload timer set for…...9.8 minutes

Advertising